Power Specifications

 

Technical specifications
Power Requirements

 

             SnapStream servers are equipped with dual hot-swap power supplies that are both redundant, and load-balancing. A single unit may be replaced without a system power-down. They also support auto detection of 100-240V and 50-60Hz power. 

Below are the server configurations and their respective power consumption statistics. 

Storage Level

Chassis Size

Total Number of Drives

Power Supply Used

Idle Draw Watts

Idle Draw Amps

Max Draw Watts

Max Draw Amps

Power Off Draw 

3 TB

3U

7

Dual 800 Watts

190

1.6

240

2.0

30 W

6 TB

3U

11

Dual 800 Watts

250

2.1

300

2.5

30 W

9 TB

3U

16

Dual 800 Watts

325

2.7

375

3.1

30 W

12 TB

4U

20

Dual 900 Watts

385

3.2

435

3.6

30 W

15 TB

4U

24

Dual 900 Watts

445

3.7

495

4.1

30 W

 

  • Best Practices 

 

Minimal Configuration 

Each system power supply unit plugged into an ‘uninterrupted power supply’ (UPS) or ‘battery backup unit’ (BBU.)  Protection provided for single system power supply unit failure, and minor power outages or failures.  

 mceclip0.png

Better Configuration 

Each system power supply unit plugged into a separate UPS or BBU.  Protection provided for single system power supply unit failure, power outages, and single UPS/BBU failure. 

 mceclip1.png

Best Configuration 

Each system power supply unit plugged into its own UPS/BBU, each of which is powered by separate, independent circuits.  Protection provided for single system power supply unit failure, power outages, single UPS/BBU failure, and single facility circuitry failure.  

 mceclip2.png

UPS VA Recommendations 

When deciding on UPS hardware, it is important to choose a solution with the appropriate VA rating.  This rating allows you to calculate the prospective uptime of a server in the event of a power failure, based on the power draw of the system.  Listed below are some approximate times for our servers based on UPS hardware with standard VA ratings*. 

 

  • Single UPS Configuration (All times approximate) 

  

Storage Level

Idle Draw Watts

Max Draw Watts

500VA

800VA

900VA

1200VA

1500VA

3 TB

190

240

3 min

15 min

15 min

15 min

20 min

6 TB

250

300

3 min 

15 min

15 min

15 min

20 min

9 TB

325

375

N/A

10 min

10 min

10 min

13 min

12 TB

385

435

N/A

6 min

6 min

6 min

9 min

15 TB

445

495

N/A

6 min

6 min

6 min

9 min



Dual UPS Configuration (All times approximate) 

Storage Level

Idle Draw Watts

Max Draw Watts

500VA

800VA

900VA

1200VA

1500VA

3 TB

190

240

9 min

25 min

27 min

33 min

38 min

6 TB

250

300

9 min 

25 min

27 min

33 min

38 min

9 TB

325

375

9 min

25 min

27 min

33 min

38 min

12 TB

385

435

3 min

15 min

15 min

22 min

24 min

15 TB

445

495

3 min

15 min

15 min

22 min

24 min

 

*These calculations are a conservative estimate based on maximum power draw with a full CPU load. 

 